- DLM6-5AF, DLM6-2.5, DLM6-5A, DLM6-5AFH, DLM6-5AFS, Electromagnetic Power Lost clutches, electromagnetic clutches manufacturers detailsDLM6-5AF DLM6-2.5 DLM6-5A, DLM6-5AFH, the DLM6-5AFS, Electromagnetic Power Lost clutch, electromagnetic clutch manufacturers
Description: (I), the main purpose: Electromagnetic Power Lost clutch for power combined with the power to open the product, mainly used in textile machinery, metal rolling machines, handling machinery and other mechanical drive system, fast driving and driven parts of the combination, separation, starting commutation function.
(Ii), the clutch can be reliably work under the following conditions:
1, the clutch installation site altitude of not more than 2000m;
2, the ambient temperature -5 ° C - +40 ° C;
3, no danger of explosion in the surrounding medium, and no gas and conductive dust enough to corrode metal and damage the insulation;
4, the clutch coil voltage fluctuations should not exceed +5% and -15% of rated voltage;
5, work in dry conditions.
(Iii), to install:
1, the installation must be washed clean, the friction surface and the clutch inner without oil and dust;
2, clutch master, slave part must axial fixed, does not allow axial movement;
3, the main driven part of the coaxial degree should not be greater than 0.1mm.
The main performance parameters
Main Technical Data
Specification
Rated Moment
Nm
Static moment
Nm
Rated voltage
DCV
Coil power consumption (20 ° C) W
Allows the maximum speed
r / min
5AF
36
40
24
148
3000